IBM 3583 library errors

Sense ASC ASCQDescription
00 00 00 No Additional Sense Code
02 04 00 The library is not ready due to an unknown cause
02 04 01 The library is becoming ready
02 04 03 The library is not ready and a manual intervention is required
02 04 83 A door is open and a magazine is missing
02 04 8D Offline
02 04 90 Library needs teaching
02 3E 00 Unknown check condition
04 15 01 A mechanical positioning error occurred
04 15 80 The accessor dropped a cartridge
04 15 81 The accessor could not pick up a cartridge
04 15 83 The accessor could not put a cartridge
04 3B 87 Cartridge stuck in tape drive
04 3B 0D The destination element is full
04 3B 0E The destination element is empty
04 3F 80 Could not erase EEPROM
04 3F 84 Could not program EEPROM
04 40 01 Cartridge in gripper at power on
04 40 80 Component failure (Comp-80)
04 40 91 Gripper failure
04 40 A0 The accessor could not move on the vertical (Y) axis
04 40 A1 The accessor could not home the vertical (Y) axis
04 40 B0 The accessor could not move on the horizontal (X) axis
04 40 B1 The accessor could not home the horizontal (X) axis
04 40 C0 The accessor could not move
04 40 E0 The accessor lost power
04 44 00 Firmware detected an internal logic failure
04 53 00 A drive did not load or unload a tape
04 53 82 Cannot lock the I/E station
04 53 83 Cannot unlock the I/E station
04 83 00 Label too short, too long or duplicate
04 83 01 Cannot read a bar code label due to scanner position
04 84 00 Firmware error
05 1A 00 Paramter List length error (bad cmd sent to library)
05 20 00 Illegal opcode in CDB (Command Data Byte - bad cmd sent to library)
05 21 01 Invalid Element address in CDB (Command Data Byte - bad cmd sent to library)
05 24 00 Invalid Field in CDB (Command Data Byte - bad cmd sent to library)
05 24 80 Attempt to write a read-only buffer (bad cmd sent to library)
05 25 00 Illegal LUN
05 26 00 Invalid field in field list (bad cmd sent to library)
05 26 02 Invalid parameter in parameter list (bad cmd sent to library)
05 26 80 Parameter data checksum failure
05 30 00 Incompatible media installed
05 3B 0D Destination element full for MOVE MEDIUM command
05 3B 0E Source element empty for MOVE MEDIUM command
05 3B 85 Destination of MOVE MEDIUM command cannot be accessor
05 3B 86 Source of MOVE MEDIUM command cannot be accessor
05 3B 87 Cartridge stuck in tape drive
05 3B 90 Source cartridge loaded into tape drive and not accessible (in use ?)
05 3B A0 Media type does not match destination media type
05 3D 00 Invalid bit in "Identity" message
05 3E 00 Incorrect LUN confguration
05 44 00 Firmware detected an internal logic failure
05 53 01 A drive did not unload a tape
05 53 80 Cartridge rejected in the I/O station because is was not properly loaded
05 53 81 I/O station is open
05 83 02 Cartridge magazine is not installed
05 83 03 Cell status and bar code questionable
05 83 04 Drive not installed
06 28 00 Door or doors opened and closed
06 28 01 I/O station opened
06 29 00 Power on, SCSI bus reset, or Bus device reset occurred
06 29 80 Reset for permanent error occurred
06 29 81 Reset into degraded mode of operation
06 2A 01 Mode parameters have been changed
06 3F 01 New firmware loaded
08 43 00 Message received at inappropriate time
08 45 00 Host rejected "Identify" message sent for reselection
08 47 00 Message system was disabled during parity error detection on SCSI bus, message system enabled but initiator rejected "Restore data pointer", or all parity error retires exhausted
08 48 00 Received an "Initiator Detected Error" or initiator rejected "Restore Data Pointer" in response to an "Initiator Detected Error" 08 4E 00 Disconnect during command processing